Knee Surgery & Related Research : eISSN 2234-2451 / pISSN 2234-0726

Download original image
Fig. 3. Bland-Altman plots for agreement of navigation and preoperative measurements. (A) Plot for preoperative supine radiographic and navigation values. (B) Plot for preoperative standing radiographic and navigation values. The Bland-Altman plot showed less discrepancy between weight bearing whole leg radiographs (WLRs) and navigation values, but the range of 95% limits of agreement was not acceptable for both the supine-positioned WLRs and weight bearing WLRs. SD: standard deviation.
Knee Surgery & Related Research 2018;30:326~333 https://doi.org/10.5792/ksrr.18.028
© Knee Surg Relat Res